A terminal with clarity
HEX, DEC or UTF-8. CR/LF endings, packet preview and optional CRC-16/Modbus.
FOR PEOPLE WHO WORK WITH HARDWARE
From the first packet to a clear reading. Send commands, read registers and discover devices in one native application.
Apple Silicon · macOS 14+ · DMG, 3.6 MiB
Read Holding Registers · CRC ✓
UINT16 · 0x0000 → 0 · 0x0001 → 1
| Address | Value | Format |
|---|---|---|
| 0 | 0 | UINT16 |
| 1 | 1 | UINT16 |
01 03 00 00 00 02 C4 0B
01 03 00 00 00 02 + CRCReady to send · HEX · CRC-16
A simplified feature demonstration. No hardware connection.
YOUR EVERYDAY ENGINEERING TOOL
For configuring automation, diagnosing connections and working with Modbus equipment. From raw bytes to device controls.
HEX, DEC or UTF-8. CR/LF endings, packet preview and optional CRC-16/Modbus.
Build Modbus requests and inspect UINT16, INT16, HEX and bit values. Explicit zero-based or one-based addressing.
Scan addresses 1–247 and serial settings. A match is confirmed by two responses with a valid CRC.
Timestamped TX/RX, filters and counters. Save commands and export a TXT log to inspect the exchange.
Profiles for selected Intesis, ONOKOM, Breezart, Hisense, Haier, CoolAutomation and RTD models. Read back state after a write.
Try the terminal, registers and controls before connecting. Switch the app language without dropping your connection.
FROM CONNECTION TO ANSWER
A USB adapter on Mac, Modbus TCP or a transparent TCP gateway.
Enter bytes in the terminal or select a function and register address.
Inspect TX/RX packets, check register values and save the log.
PLATFORMS & CONNECTIONS
The downloadable installer is for Apple Silicon Macs. Mobile capabilities depend on the device and connection type.
| Platform | Connection | Availability |
|---|---|---|
| Mac · Apple SiliconmacOS 14+ | USB / RS-485, Modbus TCP, raw TCP | Version 0.7.0 available |
| iPhoneiOS 17+ | Modbus TCP, raw TCP; no direct USB | No public build yet |
| iPadiPadOS 17+ | Network; experimental CH340 USB on M-series iPad | No public build yet |
On Mac, your adapter must expose a system serial port and switch RS-485 direction automatically. A physical bus response and hardware compatibility of all profiles still need verification. USB on iPad requires Apple entitlements and on-device testing.
Seven interface languages. Choose one or follow your system settings. Commands, addresses and bytes stay unchanged.
CH340, FTDI, CP210x and other adapters whose drivers provide a working macOS serial port. RS-485 requires automatic direction control. Opening a CH340/CH341 port and handing a request to the driver have been checked; a physical device response has not yet been verified.
Modbus TCP uses an MBAP header without CRC. A transparent TCP stream sends your bytes, such as RTU frames with CRC through a network RS-485 gateway. Baud rate and parity are configured on the gateway.
Yes. The built-in demo lets you explore commands, register reads and device controls without connecting to equipment.
A public iPhone and iPad release is not available yet. This website offers a separately signed and notarized Mac DMG for Apple Silicon.
The most recent 2,000 events are held in memory. Export them to TXT before quitting. Automatic polling is for reads; write commands are never retried automatically.
READY FOR YOUR NEXT CONNECTION
Install mmcom and start with the built-in demo. Then connect your equipment.